Catalogue UV Philips - PDF Flipbook

Catalogue UV Philips có stamp bản quyền CAMIX

120 Views
32 Downloads
PDF 0 Bytes

Download as PDF

REPORT DMCA


Knowing you’re safe

Philips UV purification lamp systems offer highest reliability,
enabling maximum protection of water and air quality

Content overview 3

4 - 5 Knowing you’re safe
6 - 11 Residential water and air purification

TUV PL-S
TUV TL Mini
12 - 21 Municipal and industrial water purification
TUV Amalgam XPT System
DynaPower System
Medium Pressure Mercury
TUV T5
22 - 29 Commercial and professional air purification
TUV PL-L
TUV T8
TUV T8 Xtra
30 - 31 The right driver for the right lamp

2

Knowing
you’re safe

As the population rises, the demand for clean and safe water increases - but so does the risk of Sustainability UV technology
pollution.Water is more and more often contaminated with different micro-organisms such as Sustainability has always been at the heart of Philips.We’re Ultra-Violet (UV) radiation is invisible to human eyes. It can be
Cryptosporidium and Giardia. Moreover, more than one billion people around the world still have leading the way towards systems that improve quality of life of subdivided into three categories, UVA, UVB and UVC. UVC
no access to safe drinking water. At the same time, the air we breathe in indoor environments can people around the world with minimum environmental impact: radiation is known to break the DNA of bacteria, viruses and spores.
be contaminated with micro-organisms such as bacteria and viruses that can make us ill. • It’s estimated that absence of a safe water supply contri­ As a result, they are rendered harmless. UV radiation can be used
for multiple purposes in water and air treatment, but is primarily
Philips Lighting provides innovative, reliable and sustainable UV lamp systems that have the power to butes to 80% of diseases and deaths in the developing employed as a disinfection process that inactivates micro-organisms
purify water and air, resulting in a healthier environment for all. world.With its UV lamp systems, Philips helps provide without chemicals. For other applications, UV is used for the removal
safe drinking water and air in a cost-effective way. of organic and inorganic chemicals, including chlorine, chloramines,
Innovation driver needs to be optimized.We are the only manufacturer • Philips UV solutions contribute to a better environment, ozone and Total Organic Carbon (TOC) emerging contaminants.
Our comprehensive portfolio of UV lamp and driver that offers a complete in-house manufactured package of because they substitute potentially dangerous chemicals.
systems is always on the forefront of innovation. Just think lamps, drivers and sleeves, ensuring the ultimate performance. • M oreover our products contain industry-leading low Benefits of UV are:
of the eXtreme Power Technology (XPT) amalgam systems Evidently, all our products are tested to the most stringent amounts of mercury, help reduce waste thanks to • Effective for all types of microorganisms, including
that contain high wattages of low pressure lamps, resulting in standards to ensure they provide the ultimate quality, their long lifetime and reduce energy use thanks to
amazing power which allows even more flexibility in system reliability and performance. their high efficacy. bacteria, viruses, fungi, and protozoa such as Cryptosporidium
design and application. Evidently, we work closely with You can recognize our most sustainable products by the and Giardia
our customers to develop and produce the most efficient When you choose Philips as a partner, you can be sure that Green Logo.The Green Logo is only awarded when the • No disinfection by-products (DBPs) of health
solutions, creating tailor-made lamp systems when required. we take complete responsibility for the system performance product offers a significant environmental improvement. concern formed
and reliability.You deal with one supplier for the total system. • UVC acts instantly
Reliability This helps to avoid problems on any compatibility failures • Low capital and operating cost
To achieve the best performance from any installation, and makes life easier for you. • Easy to operate and maintain
the delicate balance and interaction between lamp and • Does not change the taste of water
• Safe and environmentally-friendly
• No overdose issues and dose can be easily adapted to
specific needs

4 5

Residential water Philips TUV PL-S Philips TUV TL Mini TUV T5
and air purification page 8-9 page 10-11 page 20-21

The quality of the air we breathe and the water we purifiers. Combined with a filter to remove suspended Philips TUV PL-L Philips TUV T8 Philips drivers
drink has a profound effect on our health and well-being. particulates or organic materials, the result is pure, clean Page 24-25 page 26-27 page 30-31
Many people do not have access to clean drinking water. and safe water.
Impure or contaminated drinking water can cause a range
of diseases from typhoid and cholera to gastroenteritis Next to that, many households are troubled with harmful
and hepatitis A. germs that float through the air, such as the flu and
pneumonia.These can be rendered harmless through air
Households can purify their water by installing UV water purifiers equipped with Philips UV lamps and drivers.
purification systems at the point of entry in the home, at As a result, illnesses that are easily transmitted via the air
the point of use (such as the kitchen sink) or via separate are minimized and the overall air quality is improved.

6 7

Philips TUV PL-S Technical data

Philips TUV PL-S lamps are compact UVC (germicidal) lamps used in residential Type Cap- Dim. Technical Lamp UVC Lamp Useful Depreciation Packaging Packaging Ordering
water and air disinfection units.The compact size of the lamp allows for a Base no Lamp Voltage 100 Current life at useful type configu­ number
small system design and design flexibility. Philips TUV PL-S lamps offer almost TUV PL-S 5W/2P (A) (h) lifetime ration 92790...
constant UV output over their complete lifetime, for maximum security of TUV PL-S 5W/4P Wattage 0.180 9000 (%)
disinfection and high system efficacy.Thanks to the single-ended lamp base, TUV PL-S 7W/2P (W) (V) (h)
lamp replacement is easy. TUV PL-S 7W/4P G23 1 5.5 35 1.0 20 1CT 6x10 BOX 0504007
TUV PL-S 9W/2P
Main applications TUV PL-S 9W/4P 2G7 2 5.1 27 1.0 0.190 9000 15 1CT 5x10 CC 0804007
• Deactivation of bacteria, viruses TUV PL-S 11W/2P
TUV PL-S 13W/2P G23 3 7.1 46 1.6 0.175 9000 20 UNP 5x10 CC 1104008
and other micro-organisms
• Residential drinking water units 2G7 4 7.0 37 1.6 0.190 9000 20 1CT 5x10 CC 1504007
• Pond water units
• Air treatment units G23 5 9.0 60 2.4 0.170 9000 20 1CT 6x10 BOX 1704007
• Stand-alone purifiers
2G7 6 8.6 60 2.4 0.170 9000 20 1CT 6x10 BOX 1904007

G23 7 11.0 89 3.6 0.160 9000 20 1CT 6x10 BOX 2304007

GX23 8 13.0 56 3.4 0.290 9000 20 1CT 6x10 BOX 2804007

Type Sleeve Ordering number

Features Benefits TUV PL-S 5W/2P Quartz sleeve 31/129 322201953921
Short-wave UV radiation with a peak at 253.7 TUV PL-S 5W/4P Quartz sleeve 31/129 322201953921
nm (UVC) for disinfection purposes Security of effective disinfection over the TUV PL-S 7W/2P Quartz sleeve 31/129 322201953921
Protective inside coating ensures almost useful lifetime of the lamp TUV PL-S 7W/4P Quartz sleeve 31/129 322201953921
constant UV output over the complete High system efficacy because it is not required TUV PL-S 9W/2P Quartz sleeve 31/129 322201953921
lifetime of the lamp to over-design the purification system to TUV PL-S 9W/4P Quartz sleeve 31/129 322201953921
Special lamp glass filters out the 185 nm maintain effectiveness of disinfection TUV PL-S 11W/2P Quartz sleeve 31/198 322201953931
ozone-forming radiation Good environmental choice because of TUV PL-S 13W/2P Quartz sleeve 31/198 322201953931
2-Pin PL-S lamp base contains a special lowest amount of mercury
starter for almost instant starting on
electromagnetic drivers D D1 D D1 D D1
4-Pin PL-S lamps are designed for use on
electronic drivers A
B
Warning sign on lamp indicates that the C
lamp radiates UVC A
B
C

A
B
C

G23 2-pins 2G7 GX23

Dim.* A B CD D1 Dim.* A B CD D1 Dim.* A B C D D1
no. max. max. max. max. max. no. max. max. max. max. max. no. max. max. max. max. max.
1 67 83 105 28 13 2 67 83 88.1 28 13 8 139.5 155.2 178.2 28 13
3 97 112.5 135.5 28 13 4 97 112.5 119.1 28 13
5 129 145 167 28 13 6 129 145 167 28 13 * Dimensions (mm)
7 198 213.3 236 28 13

8 9

Philips TUV TL Mini Technical data

Philips TUV TL Mini lamps are slim double-ended UVC (germicidal) lamps used Type Cap-Base Dim. Technical Lamp UVC Lamp Useful Depreciation Packaging Packaging Ordering
in residential water and air disinfection units.The small 16 mm diameter of no Lamp Voltage 100 Current life at useful type configu­ number
the lamp allows for a small system design and design flexibility. Philips TUV TL (A) (h) lifetime ration
Mini lamps offer almost constant UV output over their complete lifetime, for Wattage (%)
maximum security of disinfection and high system efficacy. (W) (V) (h)

Main applications TUV 4W G5 14 29 0.9 0.17 6000 20 1FM 10x25 BOX 928000104013
• Deactivation of bacteria, viruses
TUV 6W G5 26 42 1.5 0.16 9000 20 1FM 10x25 BOX 928000704013
and other micro-organisms
• Residential drinking water units TUV 8W G5 38 56 2.1 0.15 11000 15 1FM 10x25 BOX 928001104013
• Fish pond water units
• In-duct air treatment units TUV 11W G5 2 11 34 2.6 0.33 11000 15 1FM 10x25 BOX 928002204013
• Stand alone air purifiers
TUV 16W G5 4 15 43 3.9 0.40 11000 15 1FM 10x25 BOX 928002004013

TUV 20W G5 5 20 45 6.0 0.45 11000 15 1FM 10x25 BOX 928003404013

TUV 6W 4P SE 4 Pins Single Ended 6 6.0 42 1.7 0.160 9000 20 UNP 32 927971604099

TUV 11W 4P SE 4 Pins Single Ended 6 11.0 34 2.6 0.330 9000 15 UNP 32 927971204099

TUV 16W 4P SE 4 Pins Single Ended 7 15.0 43 4.0 0.400 11000 15 UNP 32 927971404099

Features Benefits Type Sleeve Ordering number
Short-wave UV radiation with a peak at 253.7
nm (UVC) for disinfection purposes Security of effective disinfection over the TUV 11W 4P SE Quartz sleeve 25/225 322201953841
Protective inside coating ensures almost useful lifetime of the lamp TUV 16W 4P SE Quartz sleeve 25/300 322201953851
constant UV output over the complete High system efficacy because it is not required
lifetime of the lamp to over-design the purification system to D
Special lamp glass filters out the 185 nm maintain effectiveness of disinfection D
ozone-forming radiation Good environmental choice because of A
lowest amount of mercury B
Warning sign on lamp indicates that the lamp C
radiates UVC A
G5 C

Dim.* A B B C D 4-Pin Single Ended
no. max. min. max. max. max.
1 135.9 140.6 143 150.1 16 Dim. A B C D
2 212.1 216.8 219.2 226.3 16
3 283.3 293 295.4 302.5 16 no. max. max. max. max.
4 288.3 293 295.4 302.5 16
5 398 402.7 405.1 412.2 16 6 244.1 251.8 19

7 320.3 328 19

* Dimensions (mm)

10 11

Municipal and Philips TUV Philips Dynapower Philips Medium
industrial water Amalgam XPT System System Pressure Mercury
purification
page 14-15 page 16-17 page 18-19

Every government aims to provide its citizens with safe Waste water must also be disinfected before it is
and clean drinking water. If they can de-activate the discharged into the environment. Not only does this
micro-organisms in water cost-effectively by avoiding, minimize the risk to the local population, it also helps to
or reducing, the use of chlorine, all the better. Philips protect vulnerable natural eco systems in the discharge
is helping to do just that with a range of lamp systems areas. Here too, our UV lamp systems are becoming
designed to meet all the main municipal requirements. increasingly popular. Highly cost-effective, they treat
waste water without adding chemicals or residues.
Safeguarding our communities and the environment. Philips TUV T5 Philips drivers
page 20-21 page 30-31

12 13

Philips TUV Technical data
Amalgam XPT System

Philips TUV Amalgam XPT system consists of an electronic driver that operates Lamp type Cap-Base Dim. no. Lamp Lamp Lamp UVC Useful Depreciation Ordering
one TUV Amalgam XPT lamp, mounted in a sleeve.The electrical specifications Wattage Voltage Current 100 Life at useful lifetime number
are tailored to the lamp, ensuring an optimized performance of the Philips TUV TUV 130W XPT 4p-SE (W) (V) (A) (h) (h) (%) 92810...
Amalgam XPT system.Thanks to extensive testing before a lamp system is TUV 180W XPT 4p-SE 2.1 48 12000 15 1805112
released, we can ensure maximum reliability and long lifetime. TUV 200W XPT 4p-SE 1 140 70 2.1 60 12000 15 6805112
TUV 325W XPT 4p-SE 2 180 90 2.1 66 12000 15 6905112
Main applications TUV 325W XPT HO 4p-SE 3 200 100 2.1 100 12000 15 2205112
• Deactivation of bacteria, viruses and other micro-organisms TUV 330W XPT 4p-SE 4 280 141 2.1 110 12000 15 7005112
• Municipal drinking water treatment equipment TUV 800W XPT 4p-SE 5 325 158 4.6 107 12000 15 1705112
• Municipal waste water treatment equipment 6 325 72 8.0 > 240 12000 15 On request
• Process water treatment equipment 7 800 100
• Swimming pool units
• Equipment for the production of ultra-pure water, for example for the Lamp type Driver Ordering Sleeve Ordering
number number
semiconductor, pharmaceuticals and cosmetics industries (ozone version) TUV 130W XPT 9137...
TUV 180W XPT 3222 019 53891
TUV 200W XPT TUV 130W XPT driver 00729703 Quartz sleeve 28/885 9298 005 00401
TUV 325W XPT -
Features Benefits TUV 325W XPT HO TUV 180-200W XPT driver 10054695 Quartz sleeve 28/1120 3222 019 53901
Short-wave UV radiation with a peak at 253.7 TUV 330W XPT 3222 019 53901
nm (UVC) for disinfection Security of effective disinfection over the TUV 800W XPT TUV 180-200W XPT driver 10054695 On request -
Special amalgam used for highest efficiency useful lifetime of the lamp -
over wide temperature range TUV 325W XPT (HO) driver 10054995 Quartz sleeve 28/1625
Protective inside coating ensures constant Extreme reliability of driver, with annual failure
UV output over the complete lifetime of rate of less than 1% TUV 325W XPT (HO) driver 10054995 Quartz sleeve 28/1625
the lamp Approximately 10% energy savings, because
Philips electronic driver available for a lamps can be dimmed to reach the same - - On request
perfect interface UV output compared to similar lamps on
the market TUV 800W XPT driver Prototype -
Minimized amount of mercury High system efficacy because it is not required
Universal burning position possible for to over-design the purification system to All drivers are pre-heat and dimmable from 100 to 50%, except for the 130W driver
the T6 range, depending on lamp type and maintain effectiveness of disinfection
sleeve dimensions Best environmental choice because of long O
Tailor-made solutions possible reliable life, less waste and industry leading
Lamp can be made from special quartz low amount of mercury D
(open / synthetic) to maximize 185nm Ozone High efficiency during dimming thanks to
generation unique amalgam temperature control of C
the 800W lamps
4-Pin Single Ended

Dim.* C D O
no. max. nom. nom.
1 842 19 740
2 1032 19 930
3 1147 19 1040
4 1582 19 1480
5 1582 19 1480
6 1554 32 1440
7 1790 38 1600

* Dimensions (mm)

14 15

Philips Dynapower Technical data
System

Philips Dynapower system consists of an electronic DynaPower driver that Lamp type Cap-Base Lamp UVC Useful Depreciation at Ordering number
operates one or two TUV Amalgam 230W, 260W and 335W XPT lamps.This Wattage 100 Life useful lifetime 92810...
system is extremely reliable and robust.The driver allows for immediate energy TUV 230W XPT WE 4p-SE (W) (h) (h) (%)
savings compared to similar drivers on the market. Moreover, it can be dimmed 230 78 12000 15 4005112
down to 60% power level for additional energy savings. Further energy savings TUV 260W DIM XPT 4p-SE 235 87 12000 15 2805112
are realized by the TUV Amalgam XPT lamps, because they can be dimmed 300 100 12000 15 3105112
down to reach the same UV output as similar lamps on the market. TUV 335W XPT SE 4p-SE 300 100 12000 15 5705112

Main applications TUV 335W WP XPT SE 4p-SE
• Deactivation of bacteria, viruses and other micro-organisms
• Municipal drinking water treatment equipment Lamp type Driver Ordering number
• Municipal waste water treatment equipment 91371...
• Process water treatment equipment
TUV 230W XPT WE DynaPower 3229695
3229695
TUV 260W DIM XPT DynaPower 3229695
3229695
TUV 335W XPT SE DynaPower

Features Benefits TUV 335W WP XPT SE DynaPower
Operates 230W, 260W and 335W TUV Extreme reliability of driver, with annual failure
Amalgam XPT lamps rate of less than 1% 4-Pin Single Ended
Single lamp operation possible Easier to maintain compliance with
Cooler operating temperature for additional regulations thanks to reduced risk of failures dimensions C D O
energy savings Easier maintenance thanks to single lamp 25 1400
100% stress testing minimizing 0-hour failures operation, allowing to detect easily which TUV 230W XPT WE 1514 32 1400
lamps need to be replaced 32 1400
Protection against voltage peaks Dimmable up to 60% power level for TUV 260W DIM XPT 1514 32 1400
additional energy savings
Permanent overvoltage protection Best environmental choice thanks to TUV 335W XPT SE 1514
Approximately 20 seconds start-up time maximum lifetime reliability, in combination
(compared with 90 seconds for similar drivers with minimum substances, packaging and TUV 335W WP XPT SE 1514
on the market) product weight

16 17

Philips Medium Technical data
Pressure Mercury

Philips Medium Pressure Mercury lamps are available in a wide range of up to Type Tube Arc length Lamp Wattage Lamp Voltage Lamp Current UVC Irradiance
180 W per centimeter, with an arc length between 10 and 140 centimeter. diameter mm max typical typical 100 muW/cm2
The lamps can be fitted with various types of end fitting from our catalogue, HOK 10/120 mm 105 (W) (V) (A) (h) 1400
or equipped with customer special fittings, cables or pins.The lamps are made HOK 20/100 22 195 2500
from selected types of quartz glass, with transmission characteristics tailored HOK 25/120 22 250 1100 130 8.5 140 3800
to the application. HOK 35/120 22 350 5200
HOK 50/120 22 500 2100 240 9.5 250 7500
Philips Medium Pressure Mercury lamps contain sophisticated quantities of HOK 65/120 22 650 10000
mercury bromides, providing a self-cleaning halogen cycle, to control the HOK 80/120 22 800 2900 420 7.0 380 12000
depreciation of UV radiation over lamp life. HOK 105/120 22 1050 16000
HOK 140/120 22 1400 4200 490 8.5 520 21000
HOK 50/180 22 550 11300
HTK 7/30 25 700 6000 670 8.8 750 1600
HTK 7/60 14 700 3100
14 7800 840 9.2 1000

9600 1030 9.2 1200

13000 1300 9.4 1600

16800 1850 9.0 2100

Main applications 8700 430 20.0 1130
• Deactivation of bacteria, viruses and other micro-organisms
• Water treatment (waste-, drinking- or process water) 2000 1400 1.6 310
• Surface treatment
• Advanced oxidation (with special quartz glass) 4000 1400 3.1 160
• Ship ballast water treatment

Spectral output Operation Note: bulb diameters for HOK lamps are typically around Customization possible on
The lamps emit a wide band spectrum in the Philips Medium Pressure Mercury lamps 22 mm nominal for 120W/cm lamps. For lamp loading up to • Connectors
UVC range. In contrast to Low Pressure lamps, can be tailored to operate on conventional 180W/cm, the bulb diameters is around 27.5mm. HTK bulb • Pens
considerable amounts of radiation around electromagnetic or electronic drivers. diameters are 14mm nominal. Standard lamps are available • Cables
the 254 nm is emitted.The power density is Lamps in special frames for single ended (contact our sales department for details),
very high compared with Low Pressure lamps. operation are available on request. different dimensions are available on request.
Lamps can be made in special quartz to either A permissible bulb temperature for HOK
substantially lower the emission below 240 type lamps is in the 600 – 900 C range, for
nm, or to maximize radiation at 185 nm.The HTK type lamps 500 – 700 C. Permissible
former type is used in installations where nitrite pinch temperature is 300 C, higher pinch
formation must be avoided; the latter type is temperatures up to 420 C are possible using
used in installations for ozone production or the Philips patented Pinch Protection.
advanced oxidation.

Philips HOK: Maintenance Philips HOK: Maintenance
relation between UVC output and burning time relation between UVC output and burning time

100% 100%

80% 80%
UVC output in %
UVC output in %60%60%

40% 40%

20% 20%

0% 1000 2000 3000 4000 5000 6000 7000 0% 1000 2000 3000 4000 5000
0 0

Wavelength in nm Burning time in hours

18 19

Philips TUV T5 Technical data

TUV T5 lamps are single- or double-ended UVC (germicidal) lamps used in Type Cap-Base Dim. Technical Lamp UVC Lamp Useful Depre­ Packa­ Packaging Ordering
professional water and air disinfection units.The small 16 mm diameter of the TUV 25W 4P SE no Lamp Voltage 100 Current life ciation ging configu­ number
lamp allows for a small system design and design flexibility.TUV T5 lamps offer at useful type ration
almost constant UV output over their complete lifetime, for maximum security Wattage (A) (h) lifetime (%)
of disinfection and high system efficacy. (W) (V) (h)

Main applications 4 Pins Single Ended 6 23.0 82 8.0 0.350 9000 20 UNP 32 927972204099
• Deactivation of bacteria, viruses and other micro-organisms
• Industrial water disinfection equipment, e.g. for food & beverage industry TUV 36T5 HE SP Single Pin 7 40.0 94 14.0 0.425 11000 15 UNP 32 927970004099
• Small municipal water treatment systems
• Swimming pool units TUV 36T5 HO SP Single Pin 8 75.0 97 23.0 0.800 11000 15 UNP 32 927972504099
• Residential drinking water units (6, 11 and 16W lamps)
• Air treatment systems (High Output lamp versions) TUV 36T5 HO 4P SE 4 Pins Single Ended 9 75.0 97 23.0 0.800 11000 15 UNP 32 927972104099

TUV 36T5 HE 4P SE 4 Pins Single Ended 10 40.0 94 14.0 0.425 11000 15 UNP 32 927970204099

TUV 64T5 HE G5 G5 11 75.0 176 29.0 0.425 11000 15 UNP 40 928000404099

TUV 64T5 HE SP Single Pin 12 75.0 176 29.0 0.425 11000 15 UNP 32 927970504099

TUV 64T5 HO SP Single Pin 13 140.0 175 45.0 0.800 11000 15 UNP 32 927972604099

TUV 64T5 HE 2P SE 2 Pins Single Ended 14 75.0 176 29.0 0.425 11000 15 UNP 32 927970904099

TUV 64T5 HE 4P SE 4 Pins Single Ended 15 75.0 176 29.0 0.425 11000 15 UNP 32 927970704099

TUV 64T5 HE 4P SE 4 Pins Single Ended 15 75.0 176 29.0 0.425 11000 15 UNP 32 927970804099

Features Benefits TUV 64T5 HO 4P SE 4 Pins Single Ended 16 145.0 175 45.0 0.800 11000 15 UNP 32 927971104099

Short-wave UV radiation with a peak at 253.7 Security of effective disinfection over the Type Sleeve Ordering number
nm (UVC) for disinfection useful lifetime of the lamp
High system efficacy because it is not required TUV 25W 4P SE Quartz sleeve 25/530 322201953861
Small diameter to over-design the purification system to
maintain effectiveness of disinfection TUV 36T5 HO 4P SE Quartz sleeve 25/885 322201953871
Protective inside coating ensures almost Good environmental choice because of lowest
constant UV output over the complete amount of mercury TUV 36T5 HE 4P SE Quartz sleeve 25/885 322201953871
lifetime of the lamp
Special lamp glass filters out the 185 nm TUV 64T5 HE 4P SE Quartz sleeve 25/1585 322201953881
ozone-forming radiation
High temperature and UV-resistant lamp TUV 64T5 HE 4P SE Quartz sleeve 25/1585 322201953881
bases
High output versions available for optimum TUV 64T5 HO 4P SE Quartz sleeve 25/1585 322201953881
UVC output per lamp length, allowing for
further reduction of system size D
Warning sign on lamp indicates that the lamp D
radiates UVC
D
A A
A B
C C C

Single Pin 4-Pin Single Ended G5

Dim.* A C D Dim. A C D Dim. A B C D
no. max. max. max. no. max. max. max. max.
7 845.4 863.9 19 no. max. max. max. 11 1523.2 1530 1537.4 16
8 845.9 863.9 19
12 1556.6 1575.1 19 6 548.9 556.6 19 * Dimensions (mm)
13 1556.6 1575.1 19
9 845.1 853.1 19

10 845.1 853.1 19

14 1556.6 1564.5 19

15 1556.6 1564.4 19

16 1556.6 1564.4 19

20 21

Commercial Philips TUV PL-L Philips TUV T8 Philips TUV T8 Xtra
and Professional page 24-25 page 26-27 page 28-29
air purification

Increasingly, we spend more time indoors, for example infections, like the flu, moulds, pneumonia and MRSA, is Philips TUV T5 Philips drivers
at work, on trains and in aircrafts, in schools, cinemas and transmitted via the air - at a huge price, both in terms of page 20-21 page 30-31
shopping centres.The air we breathe in these environments human life and financial costs.Tuberculosis is even 100%
is anything but clean. In fact, it’s often re-circulated along transmitted via the air.
with all the bacteria, viruses, pollen, smoke and toxic gases
that are trapped along with it. Philips UV purification lamp systems provide a safe, reliable
and sustainable solution. Ideal for use in ventilation air ducts,
In hospitals this can be a real problem. Hospital acquired air disinfection units or stand-alone air purifiers, they help
infections affect around 10% of patients during their stay. protect against airborne pathogens, creating a safer and
And there is increasing evidence that up to 20% of these healthier indoor environment with the power of light.

22 23

Philips TUV PL-L Technical data

Philips TUV PL-L lamps are compact UVC (germicidal) lamps used in water and Type Cap- Dim. Technical Lamp UVC Lamp Useful Deprec­ iation Packa­ Packaging Ordering
air disinfection units.The compact size of the lamp allows for a small system design TUV PL-L 18W/4P Base no Lamp Voltage 100 Current life at useful ging configu­ number
and design flexibility. Philips TUV PL-L lamps offer almost constant UV output (A) (h) lifetime type ration 92790...
over their complete lifetime, for maximum security of disinfection and high system Wattage (%)
efficacy.Thanks to the single-ended lamp base, lamp replacement is easy. (W) (V) (h)

Main applications 2G11 2 18 60 5.5 0.370 9000 15 1CT 25 3004007
• Deactivation of bacteria, viruses
TUV PL-L 24W/4P 2G11 3 24 87 7.0 0.345 9000 15 UNP 50 3204016
and other micro-organisms
• Air disinfection systems in for example TUV PL-L 35W/4P HO 2G11 1 35 42 11.0 0.850 9000 15 1CT 25 4204007

hospitals, universities and laboratories TUV PL-L 36W/4P Secura 2G11 4 36 108 7.6 0.440 9000 15 1CT 25 9104001
• In-duct air treatment units
• Stand alone air purifiers TUV PL-L 36W/4P 2G11 5 36 105 12.0 0.440 9000 15 1CT 25 3404007
• Residential drinking water units
• Fish pond and process water units TUV PL-L 36W/4P 2G11 5 36 105 12.0 0.440 9000 15 UNP 50 3404016

TUV PL-L 55W/4P HF 2G11 6 55 103 17.0 0.540 9000 15 1CT 25 8704007

TUV PL-L 60W/4P HO 2G11 7 60 84 19.0 0.800 9000 15 1CT 25 9004007

TUV PL-L 95W/4P HO 2G11 8 90 115 27.0 0.800 9000 15 1CT 25 9804007

Type Sleeve Ordering number D D1

Features Benefits TUV PL-L 18W/4P Quartz sleeve 44/195 322201953941 2G11A
Short-wave UV radiation with a peak at 253.7 TUV PL-L 35W/4P HO Quartz sleeve 44/195 322201953941 B
nm (UVC) for disinfection purposes Security of effective disinfection over the TUV PL-L 36W/4P Quartz sleeve 44/385 322201953951 Dim.* A B C D D1C
Protective inside coating ensures almost useful lifetime of the lamp TUV PL-L 36W/4P Quartz sleeve 44/385 322201953951 no. max. max. max. max. max.
constant UV output over the complete High system efficacy because it is not required TUV PL-L 55W/4P HF Quartz sleeve 44/505 322201953961 1 195 220 225 39 18
lifetime of the lamp to over-design the purification system to TUV PL-L 60W/4P HO Quartz sleeve 44/385 322201953951 2 195 220 225 38 18
Special lamp glass filters out the 185 nm maintain effectiveness of disinfection TUV PL-L 95W/4P HO Quartz sleeve 44/505 322201953961 3 290 315 320 39 18
ozone-forming radiation Good environmental choice because of 4 405 430 437 52 18
Hight Output versions contain wind-chill lowest amount of mercury 5 385 410 415 38 18
correction for improved performance in 6 505 530 535 38 18
moving air and reducing amount of required 7 390 415 420 40 18
lamps 8 505 530 535 39 18
Warning sign on lamp indicates that the
lamp radiates UVC * Dimensions (mm)

24 25

Philips TUV T8 Technical data

TUV T8 lamps are double-ended UVC (germicidal) lamps used in professional Type Cap-Base Dim. no Technical Lamp Lamp Lamp Useful life on Useful life on Depreciation at
air disinfection units.TUV T8 lamps offer almost constant UV output over their Wattage Voltage Current EM gear HF gear useful lifetime
complete lifetime, for maximum security of disinfection and high system efficacy. TUV 10W G13 4 (W) (V) (A) (h) (h) (%)
Moreover, they have a long and reliable lifetime, which allows maintenance to be TUV 15W G13 1 0.230
planned for in advance. TUV T8 F17 G13 5 9.0 44.5 0.340 9000 - 15
TUV 25W G13 1 0.265
Main applications TUV 30W G13 2 15.9 54.0 0.600 9000 18000 10
• Air disinfection systems in professional applications TUV 36W G13 3 0.370
TUV 55W HO G13 2 16.7 72.0 0.440 9000 - 15
such as universities, hospitals, jails and laboratories TUV 75W HO G13 3 0.770
• Upper air and whole room disinfection equipment in 25.5 48.0 0.840 9000 18000 15

hospitals, intensive care units and surgery rooms 30.0 102.0 9000 18000 10
• Areas with low maintenance and/or disruptive costs
• Fish ponds and process water units 36.0 103.0 9000 18000 10

54.0 86.0 9000 18000 10

75.0 110.0 9000 18000 10

Features Benefits Type Packaging Packaging Ordering UVC 100h UVC 100h
Short-wave UV radiation with a peak at 253.7 Security of effective disinfection over the type configuration number on EM gear on HF gear
nm (UVC) for disinfection purposes useful lifetime of the lamp TUV 10W
Protective inside coating ensures constant UV Maintenance can be planned in advance, TUV 15W SLV 25 928024204005 2.5 -
output over the complete lifetime of the lamp virtually eliminating the need for expensive TUV T8 F17 SLV 25 928039004005 4.9 5.1
spot replacement of prematurely failed lamps TUV 25W SLV 25 927941904020 4.5 -
Long lifetime of 18,000 hours* High system efficacy because it is not required TUV 30W SLV 25 928039404005 7.0 7.5
to over-design the purification system to TUV 36W SLV 25 928039504005 12.0 13.1
High reliability with the lowest percentage maintain effectiveness of disinfection TUV 55W HO SLV 6 928048604003 15.0 14.7
of lamps that fail prematurely in the market TUV 75W HO SLV 6 928049504003 17.5 19.6
(90% of all lamps still operate on full output Good environmental choice because of SLV 6 928049404003 25.5 28.1
and quality after 15,000 hours*) lowest amount of mercury
Special lamp glass filters out the 185 nm
ozone-forming radiation D
High Output versions available for optimum
UVC output per lamp length, allowing for A
reduction of system size B
Warning sign on lamp indicates that the lamp C
radiates UVC
* based on operation on a Philips electronic driver G13

Dim.* A B B C D
no. max. min. max. max. max.
1 437.4 442.1 444.5 451.6 28
2 894.6 899.3 901.7 908.8 28
3 1199.4 1204.1 1206.5 1213.6 28
4 331.5 336.2 338.6 345.7 28
5 589.8 594.5 596.9 604 28

* Dimensions (mm)

26 27

Philips TUV Technical data
T8 Xtra

TUV T8 Xtra lamps are double-ended UVC (germicidal) lamps used in Type Cap-Base Dim. no Technical Lamp Lamp Lamp Useful life on Useful life on Depreciation at
professional water and air disinfection units.Thanks to the unique X-technology Wattage Voltage Current EM gear HF gear useful lifetime
TUV T8 Xtra lamps even double the life of conventional types.This extra long TUV 15W Xtra G13 1 (W) (V) (A) (h) (h) (%)
and reliable lifetime is even up to 36.000 hours when the lamps are operated TUV 25W Xtra G13 1 0.335
on HF Gear. As a result these lamps need to be replaced less often, significantly TUV 30W Xtra G13 2 15.9 54.0 0.612 18000 36000 10
reducing cost and disruption.Thanks to the reliable lifetime, maintenance can be TUV 36W Xtra G13 3 0.365
planned in advance. TUV 55W Xtra G13 2 25.5 48.0 0.440 18000 36000 15
TUV 75W Xtra G13 3 0.770
Main applications 30.0 102.0 0.835 18000 36000 10
• Air disinfection systems in professional applications such as
36.0 103.0 18000 36000 10
universities, hospitals, jails and laboratories
• Upper air and whole room disinfection equipment in hospitals, 54.0 86.0 18000 36000 10

intensive care units and surgery rooms 75.0 110.0 18000 36000 10
• Areas where absolute security of effective disinfection is crucial
• Areas where maintenance costs are high (e.g. high ceilings, Type Packaging Packaging Ordering UVC 100h UVC 100h
type configuration number on EM gear on HF gear
difficult access) and/or disruptive costs are high (e.g. areas 9280...
like operating theatres where lamp failure is unacceptable
for safety reasons) TUV 15W Xtra SLV 25 39104008 4.9 5.1

TUV 25W Xtra SLV 25 39704008 7.0 7.5

TUV 30W Xtra SLV 25 39804008 12.0 13.1

TUV 36W Xtra SLV 6 39904008 15.0 14.7

TUV 55W Xtra SLV 6 49104008 17.5 19.6

Features Benefits TUV 75W Xtra SLV 6 49904008 25.5 28.1
Short-wave UV radiation with a peak at Security of effective disinfection over the
253.7 nm (UVC) for disinfection purposes useful lifetime of the lamp D
Reduction of maintenance costs and
Protective inside coating ensures constant UV disruption thanks to doubled lifetime A
output over the complete lifetime of the lamp Maintenance can be planned in advance, B
Long lifetime of 36,000 hours* (double the virtually eliminating the need for expensive C
life of conventional types) thanks to unique spot replacement of prematurely failed lamps
X-technology High system efficacy because it is not required G13
High reliability with the lowest percentage to over-design the purification system to
of lamps that fail prematurely in the market maintain effectiveness of disinfection Dim.* A B B C D
(90% of all lamps still operate on full output Good environmental choice because of no. max. min. max. max. max.
and quality after 30,000 hours*) lowest amount of mercury 1 437.4 442.1 444.5 451.6 28
Special lamp glass filters out the 185 nm Directly replaces conventional T8 lamps, so it 2 894.6 899.3 901.7 908.8 28
ozone-forming radiation is not required to modify the system to enjoy 3 1199.4 1204.1 1206.5 1213.6 28
High Output versions available for optimum the benefits
UVC output per lamp length, allowing for * Dimensions (mm)
reduction of system size
Warning sign on lamp indicates that the lamp
radiates UVC
* based on operation on a Philips electronic driver

28 29

The right driver The right driver
for the right lamp for the right lamp

12 NC Philips Philips Electronic Philips Advance Philips Advance 12 NC Philips Philips Electronic Philips Advance Philips Advance
Electronic driver Driver Electronic driver Electromagnetic driver Electronic driver Driver Electronic driver Electromagnetic driver
50 Hz 50 Hz 60 Hz 60 Hz 50 Hz 50 Hz 60 Hz 60 Hz

TUV PL-S LC49CTP TUV T5 1CN2P60SC 1L RSM175STP
TUV PL-S 5W/2P LPL59TP Philips TUV 36T5 HE SP 1CN2P60SC 2L RSM175STP
H1B9TPW Philips TUV 36T5 HE 4P SE 1CN2P60SC 1L
TUV PL-S 5W/4P 913700422666 HF-M BLUE 105 LH TL/PL-S 230-240V H2B9TPW 913700191266 HF-P 158 TL-D EII 220-240V 50/60Hz 1CN2P60SC 2L LC25TP w/starter
TUV PL-S 7W/2P Philips TUV 36T5 HO 4P SE 913700613366 HF-P 154 TL5 HO EII 220-240V 50/60Hz 1CN2S5490C 1L
LC49CTP Philips TUV 64T5 HE 4P SE 913700191166 HF-P 136 TL-D EII 220-240V 50/60Hz 1CN2S5490C 2L LC1420CTP w/starter
LPL59TP Philips TUV 64T5 HO 4P SP IUV2S60M4LD 1L HM2SP20TP
H1B9TPW Philips TUV PL-L 913700180066 HF-P 1 60-120 PL-H 220-240V 50/60Hz IUV2S60M4LD 2L LXI140FTP
H2B9TPW Philips TUV PL-L 18W/4P
Philips TUV PL-L 24W/4P 913700198966 HF-P 180 TL5/PL-L EII 220-240V 50/60Hz 1UV2S60M4LD 1L
LC49CTP 1UV2S60M4LD 2L
TUV PL-S 7W/4P 913700421366 HF-M BLUE 109 LH TL/PL-S 230-240V RMB1P1 13S1 1L LPL59TP Philips TUV PL-L 35W/4P HO
TUV PL-S 9W/2P HF-M RED 109 SH TL/PL-S 230-240V RMB1P1 13S1 2L H1B9TPW Philips TUV PL-L 36W/4P 1UV2S18H1LD 1L
H2B9TPW 1UV2S18H1LD 2L
TUV PL-S 9W/4P 913700421366 HF-M BLUE 109 LH TL/PL-S 230-240V RMB1P1 13S1 1L Philips TUV PL-L 55W/4P HF 913700420666 HF-M RED 124 SH TL/TL5/PL-L 230-240V 1UV2S36M2LD 1L
TUV PL-S 13W/2P 913700422866 HF-M RED 109 SH TL/PL-S 230-240V RMB1P1 13S1 2L LC13TP 913700418066 HF-M BLUE 124 LH TL/TL5/PL-L 230-240V 1UV2S36M2LD 2L
LO1322TP Philips TUV PL-L 60W /4P HO 913700420666 HF-M RED 124 SH TL/TL5/PL-L 230-240V 1CN2S39 1L
H1B13TPW Philips TUV PL-L 95W/4P HO 913700418066 HF-M BLUE 124 LH TL/TL5/PL-L 230-240V 1CN2S39 2L
H2B9TPW TUV T8 and TUV T8 Xtra 1UV2S60M4LD 1L
TUV TL Mini Philips TUV 10W 913700180066 HF-P 1 60-120 PL-H 220-240V 50/60Hz 1UV2S60M4LD 2L
Philips TUV 4W LC49CTP w/starter Philips TUV 15W 1UV2S36M2LD 1L
Philips TUV 6W LPL59TP w/starter Philips TUV 25W 913700192066 HF-P 136 PL-L EII 220-240V 50/60Hz 1UV2S36M2LD 2L
Philips TUV 8W LC49CTP w/starter Philips TUV 30W 913700192366 HF-P 236 PL-L EII 220-240V 50/60Hz 1CN2S39 1L
Philips TUV 11W LPL59TP w/starter Philips TUV 36W 1CN2S39 2L
913700422666 HF-M BLUE 105 LH TL/PL-S 230-240V LC49CTP w/starter 1CN2S5490C 1L
Philips TUV 16W LPL59TP w/starter Philips TUV 55W HO 1CN2S5490C 2L
Philips TUV 20W 913700421366 HF-M BLUE 109 LH TL/PL-S 230-240V LOI322TP w/starter Philips TUV 75W HO 913700192266 HF-P 155 PL-L EII 220-240V 50/60Hz 1CN1S80 1L
TUV T5 RLQ120TP 913700192566 HF-P 255 PL-L EII 220-240V 50/60Hz 1UV2S60M4LD 1L
Philips TUV 6W 4P SE 913700422866 HF-M RED 109 SH TL/PL-S 230-240V RMB13S1 1L RL2SP20TP 1UV2S60M4LD 2L
Philips TUV 11W 4P SE RMB13S1 2L LC1420CPT w/starter 913700180066 HF-P 1 60-120 PL-H 220-240V 50/60Hz 1UV2S60M4LD 1L
913700612966 HF-P 1 14-35 TL5 HE EII 220-240V 50/60Hz HM2SP20TP
Philips TUV 16W 4P SE 913700613066 HF-P 2 14-35 TL5 HE EII 220-240V 50/60Hz 913700180066 HF-P 1 60-120 PL-H 220-240V 50/60Hz IUV2S60M4LD 1L
Philips TUV 25W 4P SE LC49CTP w/starter REL1BS40SC 1L
913700612966 HF-P 1 14-35 TL5 HE EII 220-240V 50/60Hz LPL59TP w/starter 913700648566 HF-P 118 PL-T/C III 220-240V 50/60Hz RELB2S40SC 2L
913700613066 HF-P 2 14-35 TL5 HE EII 220-240V 50/60Hz LOI322TP w/starter 913700648666 HF-P 218 PL-T/C III 220-240V 50/60Hz IUV2S36M2LD 1L
913700612966 HF-P 1 14-35 TL5 HE EII 220-240V 50/60Hz RLQ120TP 913700191066 HF-P 118 TL-D EII 220-240V 50/60Hz IUV2S36M2LD 2L
913700613066 HF-P 2 14-35 TL5 HE EII 220-240V 50/60Hz RL2SP20TP 913700191466 HF-P 218 TL-D EII 220-240V 50/60Hz 1CN2S5490C 1L
LC1420CPT w/starter 913700180066 HF-P 1 60-120 PL-H 220-240V 50/60Hz 1CN2S5490C 2L
913700421366 HF-M BLUE 109 LH TL/PL-S 230-240V HM2SP20TP 913700191166 HF-P 136 TL-D EII 220-240V 50/60Hz 1UV2S60M4LD 1L
1UV2S60M4LD 2L
913700612966 HF-P 1 14-35 TL5 HE EII 220-240V 50/60Hz 913700191166 HF-P 136 TL-D EII 220-240V 50/60Hz 1UV2S60M4LD 1L
913700613066 HF-P 2 14-35 TL5 HE EII 220-240V 50/60Hz 913700191566 HF-P 236 TL-D EII 220-240V 50/60Hz 1UV2S60M4LD 2L

913700612966 HF-P 1 14-35 TL5 HE EII 220-240V 50/60Hz 1UV2S36M2LD 1L 913700180066 HF-P 1 60-120 PL-H 220-240V 50/60Hz
913700613066 HF-P 2 14-35 TL5 HE EII 220-240V 50/60Hz 1UV2S36M2LD 2L 913700180066 HF-P 1 60-120 PL-H 220-240V 50/60Hz
913700612966 HF-P 1 14-35 TL5 HE EII 220-240V 50/60Hz 1CN2S39 1L
913700613066 HF-P 2 14-35 TL5 HE EII 220-240V 50/60Hz 1CN2S39 2L

30 31

©2010 Koninklijke Philips Electronics N.V.
All rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner.The
information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may
be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not
convey nor imply any license under patent- or other industrial or intellectual property rights.

Date of release: March 2010 / 3222 635 67959
Printed in The Netherlands


Data Loading...