Hebei Wint Technology Co., Ltd.
TEST REPORT SCOPE OF WORK vinyl (spc lvt) flooring REPORT NUMBER 210517008SHF-004 TEST DATE(S) 2021-05-17 - 2021-06-02 ISSUE DATE 2021-06-02 PAGES 5 DOCUMENT CONTROL NUMBER LFT-APAC-SHF-OP-10k(May 1, 2021) © 2021 INTERTEK
Intertek Testing Services Shenzhen Ltd. Shanghai Fengxian Branch
Intertek Testing Services Shenzhen Ltd. Shanghai Fengxian Branch Plant 5, No. 6958 Daye Road, Fengxian District, Shanghai, China Tel: 021-61136116 Fax: 021-61189921 Website: www.intertek.com
Test Report
Statement 1.This report is invalid without company’s special seal for testing on assigned page. 2.This report is invalid without authorized person’s signature. 3.This report is invalid where any unauthorized modification indicated. 4.Don’t copy this report in partial (except full copy) without any official approval in written by our company. This report is invalid without re-stamping the special seal for testing in copying report. 5.Any holder of this document is advised that this report is for the exclusive use of Intertek's Customer and is provided pursuant to the agreement between Intertek and its Customer. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. This report was made with due care within the limitation of a defined scope of work and on the basis of information, materials and instructions received from the Customer or its nominated third parties. Intertek is under no obligation to refer to or report upon any facts or circumstances which are outside the specific instructions received and accepts no responsibility to any parties whatsoever, following the issue of the report, for any matters arising outside the agreed scope of the works. The tests results are not intended to be a recommendation for any particular course of action. Customer is responsible for acting as it sees fit on the basis of such results. 6.Intertek's written consent is required to use Intertek's name or logo on the object, product or service being tested. The observations and test results in this report relate only to the sample under test. This report alone does not indicate that the item, product or service has passed any Intertek certification program. 7.The report was digital signed by Shang Hai, Intertek Group plc, please using Adobe Acrobat Reader to verify the authenticity.
Version: 1 May 2021
Page 2 of 5
LFT-APAC-SHF-OP-10k
Intertek Testing Services Shenzhen Ltd. Shanghai Fengxian Branch Plant 5, No. 6958 Daye Road, Fengxian District, Shanghai, China Tel: 021-61136116 Fax: 021-61189921 Website: www.intertek.com
Test Report
Issue Date:
2021-06-02
Intertek Report No.
210517008SHF-004
Applicant:
Hebei Wint Technology Co., Ltd.
Address:
Unit 6 Chamopagne, No. 239 Zhonghua North St., 050065, Xinhua District, Shijiazhuang City, Hebei Province, P.R.China.
Attn:
Mark
Test Type:
Performance test, samples provided by the applicant.
Product Information Product Name
vinyl (spc lvt) flooring
Sample Description
Good Condition
Brand
/
Sample Amount
25 pcs
Received Date
2021-05-17
Sample ID
Model
Specification
S210517008SHF.004
/
1220x183x4mm
Test Methods And Standards Test Standard ISO 4918:2016/Amd.1:2018 Specification Standard Test Conclusion
/ The samples were tested according to the above standards, and the results are shown in the following page.
Note: 1.This report relates specifically to the sample(s) that were drawn and provided by the applicant or their nominated third party. The reported result(s) provide no warranty or verification on the sample(s) representing any specific goods and/or shipment and only relate to the sample(s) as received and tested. 2.Test results were copied from Intertek Report No. 210517008SHF-003.
Report Authorized
Name:
Daniel Zhang
Title: Approver
Version: 1 May 2021
Name:
Sally Xie
Title: Reviewer
Page 3 of 5
Name:
Lillian Zhang
Title: Project Engineer
LFT-APAC-SHF-OP-10k
Test Report
Issue Date:
2021-06-02
Intertek Report No.
210517008SHF-004
Test Items, Method and Results: Test Item:
Castor chair test
Test Method:
ISO 4918:2016/Amd.1:2018
Conditioning:
Condition the test specimens at (23 ± 2)°C and (50 ± 5)% relative humidity for at least 24h
Test Condition:
At a temperature range of 18°C to 25 °C
Load mass:
90
kg
Test castors:
Type W
Speed of rotating platform:
20
r/min
Speed of castor assembly:
50
r/min
Total test revolutions:
25000
Mounting of the specimen:
Floating installation with click joints
r
Test Result: Type of damage
Observation (Yes/No)
Delamination
No
Opening of joints
No
Surface damage
No
Crazing
No
Maximum opening
0.03mm
Maximum height differences
0.08mm
Test Photo:
After test Page 4 of 5
Verdict
Pass
No requirement Report the result
Test Report
Issue Date:
2021-06-02
Intertek Report No.
210517008SHF-004
Appendix A: Sample Received Photo
Front View(Test surface)
Back View
Revision: NO.
Date
Changes
210517008SHF-004
2021-06-02
First issue
Page 5 of 5